PUSH-GH Series Heavy Oil Generating Sets
The H210 power range is 1,250 kW to 1,880 kW, with a speed of 1,000/900 rpm and a frequency of 50 Hz/60 Hz.
Category:
Heavy oil generator set
Keywords:
Gas generator sets, integrated power solutions
Hotline:
PUSH-GH Series Heavy Oil Generating Sets
PUSH-GH Series Heavy Oil Generating Sets
◆H210 power coverage ranges from 1250 kW to 1880 kW, with a speed of 1000/900 rpm and a frequency of 50 Hz/60 Hz.
◆ Light diesel oil MGO, heavy fuel oil HFO, biodiesel, pyrolysis oil.
◆ Compact structure, high integration, high power generation efficiency, and stable operation.
◆ Low lubricant consumption, low emissions, long major overhaul intervals, and easy maintenance.
◆ Particularly suitable for mines, stations, oil and gas fields, power plants, nuclear power plants, and newly built industrial projects.
Parameters of the PUSH-GH Series Heavy Oil Generating Sets
| Model number | PUSH1250GHH | PUSH1670GHH | PUSH1880GHH |
| Engine model | GP6L210HA3 | GP8L210HA3 | GP9L210HA3 |
| Engine rated power (kW ±5%) | 1320 | 1760 | 1980 |
| Voltage (kV) | 0.4/6.3/10.5 | 0.4/6.3/10.5 | 0.4/6.3/10.5 |
| Electrical power (kW ±5%) | 1250 | 1670 | 1880 |
| Bore/Stroke (mm) | 210/320 | 210/320 | 210/320 |
| Rotational speed (rpm) | 1000/900 | 1000/900 | 1000/900 |
| Frequency (Hz) | 50/60 | 50/60 | 50/60 |
| Average effective pressure (MPa) | 2.38 | 2.38 | 2.38 |
| Fuel consumption rate (g/kWh) | ≤195 | ≤195 | ≤195 |
| Oil consumption rate (g/kWh) | ≤0.8 | ≤0.8 | ≤0.8 |
| Dimensions (mm) | 6038×1761×3146 | 7318×1761×3255 | 7823 × 1761 × 3255 |
| Crew weight (kg) | 26000 | 32000 | 35000 |
| Annual online time (h) | ≥8000 | ||
| Overhaul time (h) | ≥50000 | ||
Modular heavy oil power plant
Application areas: mining, oilfields, remote areas, reclamation and development projects, industrial parks, commercial leasing, power plants, and more.
Advantages of containerized power stations: modular design, quick installation, short construction period, and more.
Easy transportation, remote monitoring.
Main features
Modular—Modular design of key equipment, integrated in containers.
Civil engineering is minimal—there’s little work involved in the structural engineering of the building.
Short cycle—The project has a short construction period and can be installed quickly.
Easy to transport—high overall mobility allows for quick completion of secondary relocation and site setup. Low investment—compared to power stations of similar scale, this one saves 20% in investment.
PUSH-GBH Oil-associated Gas Generator Set Technical Parameters
| Generator set model | PUSH900GBH | PUSH1150GBH | PUSH1350GBH |
| Engine model | GP6L210GBA | GP8L210GBA | GP9L210GBA |
| Electrical power (kW ±5%) | 900 | 1150 | 1350 |
| Thermal power (kW ±8%) | 788 | 1036 | 1130 |
| Electrical efficiency (%) | 40 | 40 | 41 |
| Thermal efficiency (%) | 35 | 35 | 34.2 |
| Overall efficiency (%) | 75 | 75 | 75.2 |
[1] The rated power conditions are as follows: altitude 0–500 m, atmospheric pressure 100 kPa, ambient temperature 25℃, relative humidity ≤30%; unit speed 1000 rpm, power factor 0.8. The actual operating power at the site shall be corrected according to the actual conditions such as site altitude, atmospheric pressure, ambient temperature, and humidity, in accordance with NB/T 42017.
[2] This parameter refers to test data obtained under the rated operating conditions on the company’s test bench; the data and base power represent the engine’s rated power.
[3] The electrical efficiency of the unit may be adjusted based on factors such as different gas source conditions and site environmental factors.
[4] The overall efficiency varies depending on the specific unit configuration and operating conditions.
Industrial Flue Gas/Biomass Gas Unit
Advantages of industrial flue gas/biomass gas units:
1. Power coverage: 600–850 kW.
2. Low oil consumption, low emissions, long major overhaul intervals, easy maintenance, and low operation and maintenance costs.
3. Applicable scenarios: Industrial exhaust gas, biomass gas.
Design features:
1. Innovative development, modular design, high reliability, and strong adaptability to air sources.
2. Designed and developed specifically for different concentrations of H2 and CO, catering to the varying compositional requirements of different gas sources.
3. Multi-level security design ensures the unit operates safely and reliably.
4. Intelligent control system: Reduces operational complexity and enhances user experience.
| Generator set model | PUSH600GGH | PUSH700GGH | PUSH850GGH |
| Engine model | GP12V190G | GP12V190G | GP12V190G |
| Electrical power kW | 600 | 700 | 850 |
| Average effective pressure MPa | 1.09 | 1.26 | 1.4 |
| Thermal power kW | 568 | 649 | 788 |
| Electrical efficiency % | 37 | 38 | 40 |
| Thermal efficiency % | 35 | 35 | 35 |
| Overall efficiency % | 72 | 73 | 75 |
PUSH-C Series Gas Generator Sets
| Aircraft model | PUSH350CTL |
| Engine model | K19N-G3 |
| Electrical power (kW ±5%) | 350 |
| Thermal power (kW ±8%) | 451 |
| Bore/Stroke (mm) | 159/159 |
| Rotational speed (rpm) | 1500 |
| Electrical efficiency (%) | 33.4 |
| Thermal efficiency (%) | 43 |
| Overall efficiency (%) | 76.4 |
| NOx (mg/Nm³, 5% O₂) | 500 |
| Dimensions (mm) | 2750×1076×1865 |
| Weight (kg) | 3500 |